Rexroth A2FO125/61L-VAB05 Axial Piston Hydraulic Pump

The Rexroth A2FO125/61L-VAB05 Axial Piston Hydraulic Pump is designed with high performance version, to meet your industrial operation for process flow. The pump features compact design and high efficiency in performance, best suitable for applications requiring longer life span and pressure capability.

It is convenient for our customer service staff to contact you in time
Click or drag files to this area to upload. You can upload up to 3 files.
Upload a picture of the hydraulic pump you need
For you to quickly find the hydraulic pump you need, please be sure to provide the brand model and picture of the hydraulic pump

Features

  • All-purpose high pressure pump
  • Robust pump with long service life
  • High power density
  • Compact dimensions
  • Very high total efficiency
  • Robust 40° bent-axis technology

 

 Dimensions

A2FO125:61L-VAB05 Axial Piston Hydraulic Pump Dimensions

Ports Standard Size pmax [bar]3) State6)
A, B Working port Fastening thread SAE J5182) 1 1/4 in M14 × 2; 23 deep 450 0
S Suction port Fastening thread SAE J5182) 1 1/2 in M12 × 1.75; 23 deep 30 0
T1 Drain port DIN 38525) M18 x 1.5; 12 deep 3 X4)
T2 Drain port DIN 38525) M18x 1.5; 12 deep 3 O4)
R Air bleed port DIN 38525) M12 x 1.5; 12 deep 3 X

1) To shaft collar
2) Only dimensions according to SAE J518, metric fastening thread is a deviation from the standard.
3) Depending on the application, momentary pressure peaks can occur.Keep this in mind when selecting measuring devices and fittings.
4) Depending on installation position, T1 or T2 must be connected
5) The countersink can be deeper than as specified in the standard.
6) O = Must be connected (plugged on delivery) X = Plugged (in normal operation)

Type code

Type code
Type code

Technical data

Displacement
geometric, per revolution
Vg cm³ 44.9 56.6 63 79.8 90.5 106.7 125
Nominal pressure pnom bar 400 400 400 400 400 400 400
Maximum pressure pmax bar 450 450 450 450 450 450 450
Maximum speed nnom 1) rpm 2240 2000 2000 1800 1800 1600 1600
nmax 2) rpm 4250 3750 3750 3350 3350 3000 3000
Flow at nnom qV l/min 101 113 126 144 163 171 200
Torque at pnom M Nm 286 360 401 508 576 679 796
Rotary stiffness c kNm/rad 4.65 6.97 8.11 9.1 9.69 12.49 13.65
Moment of inertia for rotary group JTW kg·m² 0.0033 0.0034 0.0035 0.0056 0.0058 0.0088 0.0091
Case volume V l 0.6 0.6 0.6 0.65 0.65 1.1 1.1
Weight (approx.) m kg 17 17 17 23 23 32.8 32.8

1) The values are applicable:
– at an abs. pressure pabs = 1 bar at the suction port S
– for the optimum viscosity range of vopt = 36 to 16 mm2/s
– with hydraulic fluid on the basis of mineral oils
2) Maximum speed (limiting speed) with increased inlet pressure pabs at suction port S, see the following diagram.

Viscosity and temperature of hydraulic fluids

Cold start νmax ≤ 1600 mm²/s NBR2) ϑSt ≥ -40 °C t ≤ 3 min, without load (p ≤ 50 bar), n ≤ 1000 rpm,
permissible temperature difference between axial piston unit and hydraulic fluid max. 25 K
FKM ϑSt ≥ -25 °C
Warm-up phase ν = 400 … 1600 mm²/s t ≤ 15 min, p ≤ 0.7 • pnom and n ≤ 0.5 • nnom
Continuous operation ν = 10 … 400 mm²/s3) NBR2) ϑ ≤ +78 °C measured at port T
FKM ϑ ≤ +103 °C
νopt = 16 … 36 mm²/s range of optimum operating viscosity and efficiency
Short-term operation νmin = 7 … 10 mm²/s NBR2) ϑ ≤ +78 °C t ≤ 3 min, p ≤ 0.3 • pnommeasured at port T
FKM ϑ ≤ +103 °C

1) If the specified temperatures cannot be maintained due to extreme operating parameters, please contact us.
2) Special version, please contact us.
3) Equates e.g. with the VG 46 a temperature range of +5 °C to +85 °C (see selection diagram)

Selection diagram

Selection diagram
Selection diagram

Finer filtration improves the cleanliness level of the hydraulic fluid, which increases the service life of the axial piston unit.

A cleanliness level of at least 20/18/15 is to be maintained according to ISO 4406.

At a hydraulic fluid viscosity of less than 10 mm²/s (e.g. due to high temperatures in short-term operation) at the drain port, a cleanliness level of at least 19/17/14 according to ISO 4406 is required.

For example, the viscosity is 10 mm²/s at:

  • HLP 32 a temperature of 73°C
  • HLP 46 a temperature of 85°C

Operating pressure range

Nominal pressure pnom 400 bar The nominal pressure corresponds to the maximum design pressure.
Maximum pressure pmax 450 bar The maximum pressure corresponds to the maximum operating pressure within the single operating period. The sum of the single operating periods must not exceed the total operating period.
      Single operating period 10 s
      Total operating period 300 h
Minimum pressure pHP min 25 bar Minimum pressure on high-pressure side (port A or B) required to prevent damage to the axial piston unit.
Rate of pressure change RA max 16000 bar/s Maximum permissible rate of pressure build-up and reduction during a pressure change over the entire pressure range.
Minimum pressure ps min 0.8 bar absolute Minimum pressure at inlet (suction port S) that is required to avoid damage to the axial piston unit. The minimum required pressure is dependent on the speed of the axial piston unit.
(see diagram “Maximum speed”)
Maximum pressure ps max 30 bar absolute
Continuous differential pressure ΔpT cont 2 bar Maximum averaged differential pressure at the shaft seal (case to ambient pressure)
Pressure peaks pT peak 10 bar t < 0.1 s

Rexroth A2FO125/61L-VAB05 Axial Piston Hydraulic Pump Service Manual

The Rexroth A2FO125/61L-VAB05 Axial Piston Hydraulic Pump Service manual may include illustrations, charts, step-by-step instructions, routines, service settings and training criteria.

Click To Download For Free

Rexroth A2FO125:61L-VAB05 Axial Piston Hydraulic Pump

Scroll to Top

Get a quick quote

It is convenient for our customer service staff to contact you in time
Click or drag files to this area to upload. You can upload up to 3 files.
Upload a picture of the hydraulic pump you need
For you to quickly find the hydraulic pump you need, please be sure to provide the brand model and picture of the hydraulic pump