Rexroth A11VO/190DRS Valve
Rexroth A11VO/190DRS Valve is a hydraulic ram that provides the smooth and cost-effective control of conveyor belts, fans and pump valves. This valve features a variable orifice design for accurate flow control of a wide range of fluids in both dry or wet applications. The valve’s body is constructed from cast iron for durability, increasing performance life.
Features
- Synchronous operation of up to 4 consumers with a wide flow range connected in parallel
- Protection against overrevving of hydraulic motors in control mode
- Constant division ratio in the case of summating flow division
- Optional preselectable or readjustable division accuracy by proportional orifice
- Optional with free wheel mode
- Double acting (dividing and summing) flow divider
- Suitable for open and closed circuits
- Integrated pressure relief and anti-cavitation valves for protecting hoses and preventing cavitation
- Series 1x
Type code
Dimensions
Technical data
General
Weight (approx.) | Without free-wheel | m | kg | 14 | 18.2 | 18.2 | 29.9 | 37.4 | 37.4 |
With free-wheel | m | kg | 14.1 | 18.3 | 18.3 | 30 | 37.5 | 37.5 | |
Installation position | Horizontal preferred | ||||||||
Operating temperature | ϑ | °C | -25 … +80 | ||||||
Standard painting | Single coat RAL 5010 |
Hydraulic
Nominal pressure | Port P, A, B, C, D | p | bar | 500 | ||
Maximum operating pressure | Port S | p | bar | 40 | ||
Maximum flow | Port P | qV | l/min | 160 | 440 | |
Hydraulic fluid temperature | ϑ | °C | -20 … +80 | |||
Viscosity range | v | mm²/s | 10 … 380 |
Electric
Voltage type | DC voltage | ||||
Supply voltage | V | ||||
Maximum control current | A | 1.76 | 1.2 | ||
Coil resistance | Cold value at 20 °C | Ω | 2.3 | 4.8 | |
Maximum warm value | Ω | 3.8 | 7.9 | ||
Duty cycle | % | 100 | |||
Maximum coil temperature | °C | 150 2) | |||
Supply voltage | V | ||||
Voltage tolerance | see diagram | ||||
Power consumption (solenoid) | W | 22 | |||
Duty cycle | see diagram | ||||
Switching time according to ISO 6403 (solenoid horizontal) | ON | ms | ≤ 80 | ||
OFF | ms | ≤ 50 | |||
Maximum switching frequency | 15000 | ||||
Maximum coil temperature | °C | 150 2) | |||
Protection class according to VDE 0470-1 (DIN EN 60529) | Connector version | K40 | IP69K with mating connector mounted and locked1) | ||
C4 | IP66 with mating connector mounted and locked1) | ||||
IP69K with Rexroth mating connector (material number R901022127)1) | |||||
Electronic controls | Mobile amplifier VT-MSPA1-100 Plug amplifier VT-SSPA1-1.., see data sheet 30116 |
1) Plug-in connectors are not included in the scope of delivery and must be ordered separately
2) Surface temperature of coil housing. Due to the arising surface temperature of the solenoid coil, European standards EN 563 and EN 982 must be observed.
Rexroth A11VO/190DRS Valve Service Manual
This service manual contains every service and repair information about Rexroth A11VO/190DRS Valve . This manual was designe forinde any service or repair at your local dealer. You can find step by step guide to help you to fix your problems in your own garage. Service manuals comes with pictures and diagrams to explain the entire process..
Click to download the manual for free
Rexroth A11VO/190DRS Valve Service Manual