Rexroth A2FE/160 61W VZL181 Motor

Rexroth A2FE/160 61W VZL181 Motor. Lightweight, compact and provide cost-effective machine performance for all motion control applications.

It is convenient for our customer service staff to contact you in time
Click or drag files to this area to upload. You can upload up to 3 files.
Upload a picture of the hydraulic pump you need
For you to quickly find the hydraulic pump you need, please be sure to provide the brand model and picture of the hydraulic pump

Features

  • Space-saving construction due to recessed mounting flange
  • Easy to install, simply slide into the mechanical gearbox
  • High power density
  • Very high total efficiency
  • High starting efficiency
  • Optional with integrated pressure relief valve
  • Optional with mounted additional valve: counterbalance valve (BVD/BVE), flushing and boost-pressure valve
  • Bent-axis design

Type code

Type code
Type code
Type code
Type code

Dimensions

Dimensions
Dimensions
Working port Size 1 1/4 in
Standard Dimensions according to SAE J518
Fastening thread 1) M14 × 2; 19 mm deep
State on delivery With protective cover (must be connected)
Drain port Size M22 × 15; 14 mm deep
Standard 2) DIN 3852
State on delivery 3) With protective cover (observe installation instructions)
Drain port Size M22 × 15; 14 mm deep
Standard 2) DIN 3852
State on delivery 3) Plugged (observe installation instructions)

Technical data

Table of values

Displacement
geometric, per revolution
Vg cm³ 250 355
Nominal pressure pnom bar 350 350
Maximum pressure pmax bar 400 400
Maximum speed 1) nnom rpm 2700 2240
nmax
Inlet flow 2) at nnom qV l/min 675 795
Torque 3) at pnom M Nm 1393 1978
Rotary stiffness c kNm/rad 73.1 96.1
Moment of inertia for rotary group JTW kg·m² 0.061 0.102
Case volume V l 2.5 3.5
Weight (approx.) m kg 82 110

1) These values are valid at:
– for the optimum viscosity range from vopt = 36 to 16 mm2/s
– with hydraulic fluid based on mineral oils
2) Restriction of input flow with counterbalance valve
3) Torque without radial force, with radial force see table “Permissible radial and axial forces of the drive shafts”

Viscosity and temperature of hydraulic fluids

Cold start νmax ≤ 1600 mm²/s NBR2) ϑSt ≥ -40 °C t ≤ 3 min, without load (p ≤ 50 bar), n ≤ 1000 rpm (size 28 to 180), n ≤ 0.25 • nnom (size 250 to 355),
permissible temperature difference between axial piston unit and hydraulic fluid max. 25 K
FKM ϑSt ≥ -25 °C
Warm-up phase ν = 400 … 1600 mm²/s t ≤ 15 min, p ≤ 0.7 • pnom and n ≤ 0.5 • nnom
Continuous operation ν = 10 … 400 mm²/s3) NBR2) ϑ ≤ +78 °C measured at port T
FKM ϑ ≤ +103 °C
νopt = 16 … 36 mm²/s range of optimum operating viscosity and efficiency
Short-term operation νmin = 7 … 10 mm²/s NBR2) ϑ ≤ +78 °C t ≤ 3 min, p ≤ 0.3 • pnommeasured at port T
FKM ϑ ≤ +103 °C

1) If the specified temperatures cannot be maintained due to extreme operating parameters, please contact us.
2) Special version, please contact us.
3) Equates e.g. with the VG 46 a temperature range of +5 °C to +85 °C (see selection diagram)

Selection diagram

Selection diagram
Selection diagram

Operating pressure range

Nominal pressure pnom see table of values The nominal pressure corresponds to the maximum design pressure.
Maximum pressure pmax see table of values The maximum pressure corresponds to the maximum operating pressure within the single operating period. The sum of the single operating periods must not exceed the total operating period.
      Single operating period 10 s
      Total operating period 300 h
Minimum pressure pHP min 25 bar Minimum pressure on high-pressure side (port A or B) required to prevent damage to the axial piston unit.
Minimum pressure at inlet (pump operating mode) pE min see diagram To prevent damage to the axial piston motor in pump mode (change of high-pressure side with unchanged direction of rotation, e.g. when braking),a minimum pressure must be guaranteed at the working port (inlet). The minimum pressure depends on the rotational speed and displacement of the axial piston unit.
Total pressure pSu 700 bar The summation pressure is the sum of the pressures at both work ports (A and B).
with integrated pressure relief valve RA max 9000 bar/s Maximum permissible rate of pressure build-up and reduction during a pressure change over the entire pressure range.
without pressure relief valve RA max 16000 bar/s
Continuous differential pressure ΔpT cont 2 bar Maximum averaged differential pressure at the shaft seal (case to ambient pressure)
Pressure peaks pT peak 10 bar t < 0.1 s

Rexroth A2FE/160 61W VZL181 Motor Service Manual

The Rexroth A2FE/160 61W VZL181 Motor Service Manual is a large manual that contains all the information you need to troubleshoot, repair, and replace major parts of your machine. With this manual in hand, you can avoid expensive and time-consuming parts replacement procedures.

Click to download the manual for free

Rexroth A2FE/160 61W VZL181 Motor Service Manual

 

 

Scroll to Top

Get a quick quote

It is convenient for our customer service staff to contact you in time
Click or drag files to this area to upload. You can upload up to 3 files.
Upload a picture of the hydraulic pump you need
For you to quickly find the hydraulic pump you need, please be sure to provide the brand model and picture of the hydraulic pump