Rexroth A2FM/1261W-VAB040 Motor

Rexroth A2FM/1261W-VAB040 motor is designed for conveyor systems. It has high efficiency, low noise and vibration. The bearings are surface mounted to reduce the speed variation due to changing temperature of oil.

It is convenient for our customer service staff to contact you in time
Click or drag files to this area to upload. You can upload up to 3 files.
Upload a picture of the hydraulic pump you need
For you to quickly find the hydraulic pump you need, please be sure to provide the brand model and picture of the hydraulic pump

Features

  • Large variety of available nominal sizes allows exact adjustment to the application
  • High power density
  • Very high total efficiency
  • High starting efficiency
  • Working ports SAE flange or thread
  • Optional with integrated pressure relief valve
  • Optional with mounted additional valve: counterbalance valve (BVD/BVE), flushing and boost-pressure valve
  • Bent-axis design

Type code

 Type code
Type code

1) Sizes 45, 56, 63, 80, 90 see data sheet 91071 (A2FM series 70)
2) Tapered shaft with threaded pin and woodruff key (DIN 6888). The torque must be transmitted via the tapered press fit.

 Type code
Type code

1) Threaded ports at the sides plugged with threaded plugs.
2) Please contact us.
3) Specify ordering code of counterbalance valve according to data sheet 95522 (BVD) respectively data sheet 95526 (BVE) separately.
4) Size 710 please contact us.
5) Specify ordering code of sensor according to data sheet 95133 (DSA) respectively data sheet 95135 (HDD) separately.

 Dimensions

 Dimensions
Dimensions
 Dimensions
Dimensions
Working port Size M18 × 15; 12 mm deep
Standard 1) DIN 3852
State on delivery With protective cover (must be connected)
Drain port Size M10 × 1; 8 mm deep
Standard 1) DIN 3852
State on delivery 2) Plugged (observe installation instructions)
Drain port Size M10 × 1; 8 mm deep
Standard 1) DIN 3852
State on delivery 2) Plugged (observe installation instructions)

Technical data

Table of values

Displacement
geometric, per revolution
Vg cm³ 4.93 10.3 12 16 22.9 28.1 32 45.6 56.1 63 80.4 90 106.7 125 160.4 180 200 250 355 500 710 1000
Nominal pressure pnom bar 315 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 350 350 350 350 350
Maximum pressure pmax bar 350 450 450 450 450 450 450 450 450 450 450 450 450 450 450 450 450 400 400 400 400 400
Maximum speed 1) nnom rpm 10000 8000 8000 8000 6300 6300 6300 5600 5000 5000 4500 4500 4000 4000 3600 3600 2750 2700 2240 2000 1600 1800
nmax 2) rpm 11000 8800 8800 8800 6900 6900 6900 6200 5500 5500 5000 5000 4400 4400 4000 4000 3000
Inlet flow 3) at nnom qV l/min 49 82 96 128 144 177 202 255 281 315 362 405 427 500 577 648 550 675 795 1000 1136 1600
Torque 4) at pnom M Nm 24.7 66 76 102 146 179 204 290 357 401 512 573 679 796 1021 1146 1273 1393 1978 2785 3955 5570
Rotary stiffness c kNm/rad 0.63 0.92 1.25 1.59 2.56 2.93 3.12 4.18 5.61 6.25 8.73 9.14 11.2 11.9 17.4 18.2 57.3 73.1 96.1 144 270 324
Moment of inertia for rotary group JTW kg·m² 0.00006 0.0004 0.0004 0.0004 0.0012 0.0012 0.0012 0.0024 0.0042 0.0042 0.0072 0.0072 0.0116 0.0116 0.022 0.022 0.0353 0.061 0.102 0.178 0.55 0.55
Case volume V l 0.17 0.17 0.17 0.2 0.2 0.2 0.33 0.45 0.45 0.55 0.55 0.8 0.8 1.1 1.1 2.7 2.5 3.5 4.2 8 8
Weight (approx.) m kg 2.5 5.4 5.4 5.4 9.5 9.5 9.5 13.5 18 18 23 23 32 32 45 45 66 73 110 155 325 336

1) These values are valid at:
– for the optimum viscosity range from vopt = 36 to 16 mm2/s
– with hydraulic fluid based on mineral oils
2) Intermittent maximum speed: overspeed for unload and overhauling processes, t < 5 s and Δp < 150 bar
3) Restriction of input flow with counterbalance valve
4) Torque without radial force, with radial force see table “Permissible radial and axial forces of the drive shafts”

Viscosity and temperature of hydraulic fluids

Cold start νmax ≤ 1600 mm²/s NBR2) ϑSt ≥ -40 °C t ≤ 3 min, without load (p ≤ 50 bar), n ≤ 1000 rpm (size 5 to 200), n ≤ 0.25 • nnom (size 250 to 1000),
permissible temperature difference between axial piston unit and hydraulic fluid max. 25 K
FKM ϑSt ≥ -25 °C
Warm-up phase ν = 400 … 1600 mm²/s t ≤ 15 min, p ≤ 0.7 • pnom and n ≤ 0.5 • nnom
Continuous operation ν = 10 … 400 mm²/s3) NBR2) ϑ ≤ +78 °C measured at port T
FKM ϑ ≤ +103 °C
νopt = 16 … 36 mm²/s range of optimum operating viscosity and efficiency
Short-term operation νmin = 7 … 10 mm²/s NBR2) ϑ ≤ +78 °C t ≤ 3 min, p ≤ 0.3 • pnommeasured at port T
FKM ϑ ≤ +103 °C

1) If the specified temperatures cannot be maintained due to extreme operating parameters, please contact us.
2) Special version, please contact us.
3) Equates e.g. with the VG 46 a temperature range of +5 °C to +85 °C (see selection diagram)

Selection diagram

Selection diagram
Selection diagram

Operating pressure range

Nominal pressure pnom see table of values The nominal pressure corresponds to the maximum design pressure.
Maximum pressure pmax see table of values The maximum pressure corresponds to the maximum operating pressure within the single operating period. The sum of the single operating periods must not exceed the total operating period.
      Single operating period 10 s
      Total operating period 300 h
Minimum pressure pHP min 25 bar Minimum pressure on high-pressure side (port A or B) required to prevent damage to the axial piston unit.
Minimum pressure at inlet (pump operating mode) pE min see diagram To prevent damage to the axial piston motor in pump mode (change of high-pressure side with unchanged direction of rotation, e.g. when braking),a minimum pressure must be guaranteed at the working port (inlet). The minimum pressure depends on the rotational speed and displacement of the axial piston unit.
Total pressure pSu 700 bar The summation pressure is the sum of the pressures at both work ports (A and B).
with integrated pressure relief valve RA max 9000 bar/s Maximum permissible rate of pressure build-up and reduction during a pressure change over the entire pressure range.
without pressure relief valve RA max 16000 bar/s
Continuous differential pressure ΔpT cont 2 bar Maximum averaged differential pressure at the shaft seal (case to ambient pressure)
Pressure peaks pT peak 10 bar t < 0.1 s

Rexroth A2FM/1261W-VAB040 Motor Service Manual

The Rexroth A2FM/1261W-VAB040 Motor Service Manual is a collection of service and repair information for operating and maintaining the Rexroth model A2FM/1261W-VAB040. The information regarding maintenance and repair procedures as well as fault diagnosis for the motor drive is compiled into this manual.

Click to download the manual for free

Rexroth A2FM1261W-VAB040 Motor Service Manual

 

 

Scroll to Top

Get a quick quote

It is convenient for our customer service staff to contact you in time
Click or drag files to this area to upload. You can upload up to 3 files.
Upload a picture of the hydraulic pump you need
For you to quickly find the hydraulic pump you need, please be sure to provide the brand model and picture of the hydraulic pump