Rexroth A4VTG/90 Valve
Rexroth A4VTG/90 Valve is a hollow region type ball valve with Fluid gate design. Before installing the ball check valves, you may need to backfill some grease in between the sealing surfaces on both ends of the ball check valves. The A4V TGV series valves are available with two different types of fluid gates; spring-loaded or liquid filled, both acting as shock absorbers.
Features
- Synchronous operation of up to 4 consumers with a wide flow range connected in parallel
- Protection against overrevving of hydraulic motors in control mode
- Constant division ratio in the case of summating flow division
- Optional preselectable or readjustable division accuracy by proportional orifice
- Optional with free wheel mode
- Double acting (dividing and summing) flow divider
- Suitable for open and closed circuits
- Integrated pressure relief and anti-cavitation valves for protecting hoses and preventing cavitation
- Series 1x
Type code
Dimensions
Technical data
General
Weight (approx.) | Without free-wheel | m | kg | 14 | 18.2 | 18.2 | 29.9 | 37.4 | 37.4 |
With free-wheel | m | kg | 14.1 | 18.3 | 18.3 | 30 | 37.5 | 37.5 | |
Installation position | Horizontal preferred | ||||||||
Operating temperature | ϑ | °C | -25 … +80 | ||||||
Standard painting | Single coat RAL 5010 | ||||||||
Hydraulic | |||||||||
Nominal pressure | Port P, A, B, C, D | p | bar | 500 | |||||
Maximum operating pressure | Port S | p | bar | 40 | |||||
Maximum flow | Port P | qV | l/min | 160 | 440 | ||||
Hydraulic fluid temperature | ϑ | °C | -20 … +80 | ||||||
Viscosity range | v | mm²/s | 10 … 380 |
Electric
Voltage type | DC voltage | ||||
Supply voltage | V | ||||
Maximum control current | A | 1.76 | 1.2 | ||
Coil resistance | Cold value at 20 °C | Ω | 2.3 | 4.8 | |
Maximum warm value | Ω | 3.8 | 7.9 | ||
Duty cycle | % | 100 | |||
Maximum coil temperature | °C | 150 2) | |||
Supply voltage | V | ||||
Voltage tolerance | see diagram | ||||
Power consumption (solenoid) | W | 22 | |||
Duty cycle | see diagram | ||||
Switching time according to ISO 6403 (solenoid horizontal) | ON | ms | ≤ 80 | ||
OFF | ms | ≤ 50 | |||
Maximum switching frequency | 15000 | ||||
Maximum coil temperature | °C | 150 2) | |||
Protection class according to VDE 0470-1 (DIN EN 60529) | Connector version | K40 | IP69K with mating connector mounted and locked1) | ||
C4 | IP66 with mating connector mounted and locked1) | ||||
IP69K with Rexroth mating connector (material number R901022127)1) | |||||
Electronic controls | Mobile amplifier VT-MSPA1-100 Plug amplifier VT-SSPA1-1.., see data sheet 30116 |
1) Plug-in connectors are not included in the scope of delivery and must be ordered separately
2) Surface temperature of coil housing. Due to the arising surface temperature of the solenoid coil, European standards EN 563 and EN 982 must be observed.
Rexroth A4VTG/90 Valve Service Manual
This service manual describes functions, theory of electrical and mechanical operations, maintenance and repair procedures of Rexroth A4VTG/90 Valve series. Reading this service manual will help you improve product reliability, reduce the cost of ownership, minimize the risks of unexpected failures and assure prolong equipment life cycle.
Click to download the manual for free
Rexroth A4VTG/90 Valve Service Manual