Rexroth PV/23 Valve
Rexroth PV/23 Valve is designed for use in refrigeration and air conditioning systems. It is used to switch the direction of flow or shut off on and off.The main and quality assurance departments of the company carefully check each valve before delivery, to ensure that this product has good performance, long life and stability.
Features
- Temperature proportional pressure adjustment by thermostat
- Compact design
- Energy saving
- Very high repetition accuracy
- Series 2x
Type code
Dimensions
1 Name plate
2 Width across flats 32A/F, Tightening torque MT = 50 Nm
3 Installation space in the cooling circuit
4 Port P, T
5 Installation cavity
Technical data
General
Weight (approx.) | m | kg | 0.8 | |
Installation position | any | |||
Ambient temperature | ϑ | °C | -20 … +80 | |
Standard painting | Single coat RAL 5010 |
Hydraulic
Nominal pressure up to | p | bar | 280 | ||
Maximum inlet pressure | Port P | p | bar | 315 | |
Maximum tank pressure 1) | Port T | p | bar | 0.5 | |
Maximum flow | qV | l/min | 3 | ||
Maximum hysteresis | °C | 4 | |||
Repeat accuracy | % | < ± 2 | |||
Hydraulic fluid temperature | ϑ | °C | -20 … +80 | ||
Viscosity range | v | mm²/s | 2.8 … 300 |
1) The port must be routed to reservoir depressurized and separate.
Rexroth PV/23 Valve Service Manual
Rexroth PV/23 Valve Service Manual is written for those who want to find the information on their own. With the cool tips I found in this book, you will be able to fix your problems and find things out quickly. This user guide contains step by step instruction to help you with your Rexroth PV/23 Valve.