Rexroth A2FE/180 61W-VZL181 Motor

Rexroth A2FE/180 61W-VZL181 Motor is a high-performance product. It has many uses, including the automotive industry, mechanical engineering, and electrotechnical field. The high efficiency of the Rexroth A2FE/180 61W-VZL181 Motor makes it an ideal choice to improve performance and increase savings for businesses.

It is convenient for our customer service staff to contact you in time
Click or drag files to this area to upload. You can upload up to 3 files.
Upload a picture of the hydraulic pump you need
For you to quickly find the hydraulic pump you need, please be sure to provide the brand model and picture of the hydraulic pump

Features

  • Very high power density
  • Very high total efficiency
  • High starting efficiency
  • Short installation length
  • Robust 40° bent-axis technology
  • Optional with integrated flushing valve

Type code

Type code
Type code

Dimensions

Dimensions
Dimensions

Technical data

Table of values

Displacement
geometric, per revolution
Vg cm³ 56.6 63 81.7 90.5 108.8
Maximum pressure pmax bar 420 420 420 420 420
Maximum speed nnom 1) rpm 3750 3750 3375 3375 3000
nmax 2) rpm 4125 4125 3700 3700 3300
Inlet flow at nnom = 300 bar qV l/min 210 236 270 304 326
Torque 3) at pnom = 300 bar M Nm 270 301 390 432 519
Rotary stiffness c kNm/rad 6.83 8.09 7.94 9.84 10.9
Moment of inertia for rotary group JTW kg·m² 0.0032 0.0032 0.0034 0.0054 0.0061
Case volume V l 0.6 0.6 0.6 0.65 0.65
Weight (approx.) m kg 17 17 17 23 23

1) These values are valid at:
– for the optimum viscosity range from vopt = 36 to 16 mm2/s
– with hydraulic fluid based on mineral oils
2) Intermittent maximum speed: overspeed for unload and overhauling processes, t < 5 s and Δp < 150 bar
3) Torque without radial force, with radial force see table “Permissible radial and axial forces of the drive shafts”

Viscosity and temperature of hydraulic fluids

Cold start νmax ≤ 1600 mm²/s NBR2) ϑSt ≥ -40 °C t ≤ 3 min, without load (p ≤ 50 bar), n ≤ 1000 rpm,
permissible temperature difference between axial piston unit and hydraulic fluid max. 25 K
FKM ϑSt ≥ -25 °C
Warm-up phase ν = 400 … 1600 mm²/s t ≤ 15 min, p ≤ 0.7 • pnom and n ≤ 0.5 • nnom
Continuous operation ν = 10 … 400 mm²/s3) NBR2) ϑ ≤ +78 °C measured at port T
FKM ϑ ≤ +103 °C
νopt = 16 … 36 mm²/s range of optimum operating viscosity and efficiency
Short-term operation νmin = 7 … 10 mm²/s NBR2) ϑ ≤ +78 °C t ≤ 3 min, p ≤ 0.3 • pnommeasured at port T
FKM ϑ ≤ +103 °C

1) If the specified temperatures cannot be maintained due to extreme operating parameters, please contact us.
2) Special version, please contact us.
3) Equates e.g. with the VG 46 a temperature range of +5 °C to +85 °C (see selection diagram)

Selection diagram

Selection diagram
Selection diagram

Operating pressure range

Maximum pressure pmax 420 bar The maximum pressure corresponds to the maximum operating pressure within the single operating period. The sum of the single operating periods must not exceed the total operating period.
      Single operating period 10 s
      Total operating period 200 h
Minimum pressure pHP min 25 bar Minimum pressure on high-pressure side (port A or B) required to prevent damage to the axial piston unit.
Minimum pressure at inlet (pump operating mode) pE min see diagram To prevent damage to the axial piston motor in pump mode (change of high-pressure side with unchanged direction of rotation, e.g. when braking),a minimum pressure must be guaranteed at the working port (inlet). The minimum pressure depends on the rotational speed and displacement of the axial piston unit.
Total pressure pSu 700 bar The summation pressure is the sum of the pressures at both work ports (A and B).
with integrated pressure relief valve RA max 9000 bar/s Maximum permissible rate of pressure build-up and reduction during a pressure change over the entire pressure range.
without pressure relief valve RA max 16000 bar/s
Continuous differential pressure ΔpT cont 2 bar Maximum averaged differential pressure at the shaft seal (case to ambient pressure)
Pressure peaks pT peak 10 bar t < 0.1 s

Rexroth A2FE/180 61W-VZL181 Motor Service Manual

Rexroth A2FE/180 61W-VZL181 Motor Service Manual contains maintenance schedule and the repair procedures you need. Updating hardware items appropriately can avoid major troubles in the future. When your equipment is not used for a long time, make sure to check up this manual before use again. This motor service manual will help you understand how to do routine service and repair on Rexroth A2FE/180 61W-VZL181 Motor and prolong its life.

Click to download the manual for free

Rexroth A2FE180 61W-VZL181 Motor Service Manual

 

 

Scroll to Top

Get a quick quote

It is convenient for our customer service staff to contact you in time
Click or drag files to this area to upload. You can upload up to 3 files.
Upload a picture of the hydraulic pump you need
For you to quickly find the hydraulic pump you need, please be sure to provide the brand model and picture of the hydraulic pump