Rexroth A2FE/180 61W-VZL181 Motor
Rexroth A2FE/180 61W-VZL181 Motor is a high-performance product. It has many uses, including the automotive industry, mechanical engineering, and electrotechnical field. The high efficiency of the Rexroth A2FE/180 61W-VZL181 Motor makes it an ideal choice to improve performance and increase savings for businesses.
Features
- Very high power density
- Very high total efficiency
- High starting efficiency
- Short installation length
- Robust 40° bent-axis technology
- Optional with integrated flushing valve
Type code
Dimensions
Technical data
Table of values
Displacement geometric, per revolution |
Vg | cm³ | 56.6 | 63 | 81.7 | 90.5 | 108.8 | |
Maximum pressure | pmax | bar | 420 | 420 | 420 | 420 | 420 | |
Maximum speed | nnom 1) | rpm | 3750 | 3750 | 3375 | 3375 | 3000 | |
nmax 2) | rpm | 4125 | 4125 | 3700 | 3700 | 3300 | ||
Inlet flow | at nnom = 300 bar | qV | l/min | 210 | 236 | 270 | 304 | 326 |
Torque 3) | at pnom = 300 bar | M | Nm | 270 | 301 | 390 | 432 | 519 |
Rotary stiffness | c | kNm/rad | 6.83 | 8.09 | 7.94 | 9.84 | 10.9 | |
Moment of inertia for rotary group | JTW | kg·m² | 0.0032 | 0.0032 | 0.0034 | 0.0054 | 0.0061 | |
Case volume | V | l | 0.6 | 0.6 | 0.6 | 0.65 | 0.65 | |
Weight (approx.) | m | kg | 17 | 17 | 17 | 23 | 23 |
1) These values are valid at:
– for the optimum viscosity range from vopt = 36 to 16 mm2/s
– with hydraulic fluid based on mineral oils
2) Intermittent maximum speed: overspeed for unload and overhauling processes, t < 5 s and Δp < 150 bar
3) Torque without radial force, with radial force see table “Permissible radial and axial forces of the drive shafts”
Viscosity and temperature of hydraulic fluids
Cold start | νmax ≤ 1600 mm²/s | NBR2) | ϑSt ≥ -40 °C | t ≤ 3 min, without load (p ≤ 50 bar), n ≤ 1000 rpm, permissible temperature difference between axial piston unit and hydraulic fluid max. 25 K |
FKM | ϑSt ≥ -25 °C | |||
Warm-up phase | ν = 400 … 1600 mm²/s | t ≤ 15 min, p ≤ 0.7 • pnom and n ≤ 0.5 • nnom | ||
Continuous operation | ν = 10 … 400 mm²/s3) | NBR2) | ϑ ≤ +78 °C | measured at port T |
FKM | ϑ ≤ +103 °C | |||
νopt = 16 … 36 mm²/s | range of optimum operating viscosity and efficiency | |||
Short-term operation | νmin = 7 … 10 mm²/s | NBR2) | ϑ ≤ +78 °C | t ≤ 3 min, p ≤ 0.3 • pnommeasured at port T |
FKM | ϑ ≤ +103 °C |
1) If the specified temperatures cannot be maintained due to extreme operating parameters, please contact us.
2) Special version, please contact us.
3) Equates e.g. with the VG 46 a temperature range of +5 °C to +85 °C (see selection diagram)
Selection diagram
Operating pressure range
Maximum pressure | pmax | 420 bar | The maximum pressure corresponds to the maximum operating pressure within the single operating period. The sum of the single operating periods must not exceed the total operating period. |
Single operating period | 10 s | ||
Total operating period | 200 h | ||
Minimum pressure | pHP min | 25 bar | Minimum pressure on high-pressure side (port A or B) required to prevent damage to the axial piston unit. |
Minimum pressure at inlet (pump operating mode) | pE min | see diagram | To prevent damage to the axial piston motor in pump mode (change of high-pressure side with unchanged direction of rotation, e.g. when braking),a minimum pressure must be guaranteed at the working port (inlet). The minimum pressure depends on the rotational speed and displacement of the axial piston unit. |
Total pressure | pSu | 700 bar | The summation pressure is the sum of the pressures at both work ports (A and B). |
with integrated pressure relief valve | RA max | 9000 bar/s | Maximum permissible rate of pressure build-up and reduction during a pressure change over the entire pressure range. |
without pressure relief valve | RA max | 16000 bar/s | |
Continuous differential pressure | ΔpT cont | 2 bar | Maximum averaged differential pressure at the shaft seal (case to ambient pressure) |
Pressure peaks | pT peak | 10 bar | t < 0.1 s |
Rexroth A2FE/180 61W-VZL181 Motor Service Manual
Rexroth A2FE/180 61W-VZL181 Motor Service Manual contains maintenance schedule and the repair procedures you need. Updating hardware items appropriately can avoid major troubles in the future. When your equipment is not used for a long time, make sure to check up this manual before use again. This motor service manual will help you understand how to do routine service and repair on Rexroth A2FE/180 61W-VZL181 Motor and prolong its life.
Click to download the manual for free
Rexroth A2FE180 61W-VZL181 Motor Service Manual
Related products
-
A2FE Series Axial piston fixed motor
Rexroth A2FE107/61W-VZL181 Hydraulic Pump
Rated 0 out of 5Read more